RIT will permanently shut down the RIT Wiki (Confluence wiki) on February 2, 2024. Review the Wiki Shut Down Overview for information on alternative tools, exporting content from the wiki, and other FAQs.
Date
Wed, October 28th
Attendees
- Jared Bandru
- Ben Hebert
- Anthony Bacchetta
- Jay Mantini
Bryce Salmi – Relativity Space
- Brahm Soltes – RIT Launch Initiative
- Kevin Rinehart – RIT Launch Initiative
Goals
- Get feedback from customer of implementation on sensor interfaces and design work performed
Agenda and discussion notes
| Time | Item | Who | Notes |
|---|---|---|---|
| 2 min | System Level Overview | Joseph Even | Notes/discussion here |
| 10 min | ADC Selection/Configuration/Implementation | Joseph Even | Notes/discussion here |
| 10 min | IEPE Interface | Joseph Even | Notes/discussion here |
| 6 min | Full-Bridge Interface | Joseph Even | Notes/discussion here |
| 8 min | Thermocouple Interface | Jared Bandru | Notes/discussion here |
| 8 min | Current Loop Interface | Anthony Bacchetta | Notes/discussion here |
| 8 min | Ethernet Implementation | Anthony Bacchetta | Notes/discussion here |
| 6 min | Micro/Software | Jay Mantini | Notes/discussion here |
| 12 min | Voltage Regulation | Jared Bandru | Notes/discussion here |
| 4 min | Box Construction | Ben Hebert | Notes/discussion here |
| 2 min | Data Visualization | Ben Hebert | Notes/discussion here |
| 2 min | Risk Management Update | Jared Bandru | Notes/discussion here |
Issues Raised
- ADC Voltage reference error may be a significant portion of error
- Current ADC Selection should be revisited due to SPI configuration
- In general, anything which alters a signal adds error, this should be considered for all subsystems
- A MAX Breakout should be used for thermocouple testing rather than SparkFun
- Might be almost impossible to source a current limiting diode over 18 mA for current loop
- Something should be added in the data output to indicate if a data point is new or stale
- USB and LDO power draws can conflict, may want to raise LDO voltage and add a diode to correct it
- Can decouple saved data from visualized data
Action items
- Select alternative ADC